1800 Results found

3 Flow Measurement Sites with one Transmitter

The manufacturer presents a transmitter capable of simultaneously measuring up to three different measurement places with 9 flow velocity sensors in total. This means less installation expenses, low space requirements for installation in control cabinets and simultaneous access to 3 measurement site

Flow Rate Measurement in full Pipes using the Transit Time Method

Particularly in large diameters the relevance of water volume measurement is growing. The challenge with cooling water or fresh water processes is to generate accurate flow recordings or to document and to control individual consumptions and withdrawal quantities. Flow detection, however, particular

Flow Metering using Radar for Ex-Zone 1

The OFR flow sensor by NIVUS GmbH was approved for use in Ex-Zone 1 by TÜV Nord. In addition to ATEX approval required mainly in Europe the company was approved according to IECEx standard which is preferably demanded in English-speaking countries. This allows contactless flow measurements in many a

NivuFlow 750 awarded MCERTS certification

Field trials which form a part of the testing process were conducted at WWTP of Eppingen, Germany. The NivuFlow 750 including the Correlation Sensor is intended to be used for continuous flow measurement in slight to heavy polluted media with various compositions. The flowmeter can be operated in pa

NivuFlow Stick awarded independent verification

Today, NIVUS is delighted to announce that the NivuFlow Stick has received an independent calibration certificate from METAS, the Federal Institute of Metrology in Switzerland. “This is a significant achievement,” explains Christian Koch, Head of Product Management at NIVUS. “The calibration certifi

NivuFlow 600 WS - Transmitter for precise drinking water flow measurements

The measurement system stands out with its simple installation without the need to interrupt the process as well as with its very high measurement accuracy. The IP68 clamp-on sensors are clamped onto the pipe from the outside. This uninterruptible mounting means that it is not necessary to open and,

NIVUS UK welcome Alistair MacKinnon

Twenty-five years of experience with level and flow instrumentation supplying the water and waste water industry predestine him to further expand NIVUS’ presence in the UK. He was a member of the UK Pump Centre committee for over 7 years and has been involved with many product innovations from low p

NivuFlow Stick specifications confirmed and validated at the METAS tow tank

NIVUS tested their new acoustic echo correlation velocimeter NivuFlow Stick in an independent tow operated by the Federal Institute of Metrology (METAS). The Swiss tow tank, was the instruments supplier first choice for the measurements. The calibration facility is accredited to ISO 17025/2017 and t

InSchuKa4.0": Preparing the wastewater network for the consequences of climate change

Climate change poses enormous challenges to society in general and water management in particular. Floods or inundations caused by heavy rainfall are occurring more and more frequently in Germany and often cause great damage to people and the environment, for example, due to the uncontrolled dischar

Simple and accurate flow measurement of surface water bodies in accordance with ISO 748:2021

Water and environmental agencies carry out discharge measurements in accordance with ISO guidelines and ISO 748 outlines methods for determining the velocity and the cross-section area in open channels as well as procedures for calculating the discharge. In the new 2021 edition of ISO 748, the NIVUS

Hello
We are glad to have you here! For any question regarding water or digitisation we are happy to answer you call or your email message.
Team NIVUS
Im Täle 2
75031 Eppingen